Stainless steel process piping in a production plant
High-power tank and vessel heating

Flanged Immersion Heaters

Hairpin elements welded or brazed to a pipe flange, bolted to a matching nozzle on the tank or vessel.

Flanged immersion heater, side view Terminal enclosure Flange Cold section Heated length (hairpin elements)

Schematic illustration drawn for ECC, not to scale.

01Product description

A flanged immersion heater consists of hairpin tubular elements welded or brazed to a flange, with a terminal enclosure on the outside. The flange bolts to a matching flanged nozzle on a tank or pressure vessel. Because the flange can carry many elements, this design covers higher power ratings than threaded heaters and is the core of most circulation heaters.

02Operating principle

Each element converts electrical energy into heat in its resistance coil; the heat flows through the insulation and sheath into the liquid. The flange seals the opening and supports the element bundle, and the terminal enclosure houses the electrical connections and, when specified, thermostats or thermocouple connections.

03Industrial applications

  • Large water and process tanks
  • Oil and heat transfer fluid tanks
  • Pressure vessels and the core of circulation heaters
  • Heating of liquids and gases in tanks and vessels

04Technical characteristics

  • Flange sizes and pressure classes defined by the vessel nozzle (commonly ANSI/ASME flanges)
  • Multiple hairpin elements wired for single- or three-phase supply
  • Element sheaths in steel, stainless steel or nickel alloys
  • Terminal enclosures for general purpose, moisture-resistant or hazardous areas
  • Optional built-in sensors and over-temperature protection

05Advantages

  • High kilowatt capacity in a single assembly
  • The element bundle can be removed as one unit for inspection or replacement
  • Suitable for pressurized vessels when the flange rating matches
  • Element count and watt density can be tailored to the liquid

06Selection variables

  • Medium being heated, its chemistry and its viscosity across the temperature range
  • Required power (kW) for heat-up and for holding temperature, including heat losses
  • Operating temperature and maximum allowable sheath temperature
  • Allowable watt density for the medium and flow condition
  • Sheath material compatible with the medium and the temperature
  • Supply voltage, number of phases and circuit arrangement
  • Terminal enclosure rating for the installation area (general purpose, moisture-resistant or hazardous location)
  • Temperature control and over-temperature protection
  • Flange size, pressure class and facing that match the vessel nozzle
  • Immersion length available inside the vessel

07Installation considerations

  • Confirm the nozzle is long and straight enough for the element bundle and that internal supports or baffles do not interfere.
  • Use the gasket and bolt torque specified for the flange rating.
  • Keep the heated section submerged; avoid placing elements where sediment accumulates.
  • Allow space outside the vessel to withdraw the bundle for maintenance.

08Technical information

Flanged heaters are usually sized from the energy needed to bring a tank to temperature in a given time, and then checked for watt density.

Heat-up power: P (kW) = W (lb) × cp (Btu/lb·°F) × ΔT (°F) × SF ÷ (3,412 × t)
Water: W (lb) = volume (US gal) × 8.34

cp = specific heat · ΔT = temperature rise · SF = safety factor · t = heat-up time (h) · 3,412 Btu = 1 kWh.

Worked example

Heat 500 US gal of water from 60 °F to 140 °F in 2 hours, with a 1.2 safety factor:

W = 500 × 8.34 = 4,170 lb
P = 4,170 × 1.0 × 80 × 1.2 ÷ (3,412 × 2) = 58.7 kW → select a 60 kW heater

Watt density check with 6 hairpin elements of 0.475 in and 60 in of heated length per leg:

A = π × 0.475 × 60 × (6 × 2) = 1,074 in²
WD = 60,000 W ÷ 1,074 in² = 55.8 W/in²

The result falls inside the typical range for water (45–75 W/in²). Heat losses from the tank are evaluated separately and added to the power.

Request information on flanged immersion heaters

Share your application data; we will reply with the next steps and a quotation where possible.