Immersion Heaters
Heating elements placed directly in the liquid, transferring heat by conduction and convection into the medium.
Complete heating loops: heater, controls, sensors, power switching and the heat balance behind them.
Schematic illustration drawn for ECC, not to scale.
Process heating combines heaters with the controls, sensors, power switching and piping needed to hold a process at temperature. Correct sizing starts from a heat balance of the process rather than from the heater catalog.
Sizing follows three basic steps: determine the power needed to bring the process to temperature in the desired time; calculate the power needed to maintain it, covering losses; and select the number and type of heaters to supply that power.
The heater must cover the heat-up of the material and the losses of the system, with a margin for unknowns.
Heat 300 US gal of oil (SG 0.87, cp 0.47 Btu/lb·°F) from 70 °F to 250 °F in 3 hours. Estimated system losses at operating temperature: 2.5 kW. Safety factor 1.2.
The losses value in this example is an assumption for illustration; in a real project it comes from the insulation, surfaces and piping of the system. The heat-up estimator applies the first formula.
Share your application data; we will reply with the next steps and a quotation where possible.
Heating elements placed directly in the liquid, transferring heat by conduction and convection into the medium.
Hairpin elements welded or brazed to a pipe flange, bolted to a matching nozzle on the tank or vessel.
Elements brazed or welded into a threaded hex plug that screws into a tank fitting or half coupling.